AI-07155-KS
Arrow Temporary Pacing Catheter with Shrouded Pins / Introducer Kit 5F
$24.00
eaches
In Stock: 38 Eaches
Expiration:
Expired
Express: Need it tomorrow? Order in next 2 hours 8 minutes and choose overnight shipping at checkout.
The item listed above is expired and may be used for educational, training, and non-clinical research purposes only. Any product information appearing below, including the product indication statement, pertains to an in-date item only.
Description
Teleflex Arrow Temporary Pacing Catheter with Shrouded Pins/Introducer Kit
Item # AI-07155-KS
Manufacturer: Teleflex
Contents
| One: | Temporary Pacing Catheter: 5 Fr. 110 cm Bipolar Balloon |
| One: | Sheath: 6 Fr. x 4" (10 cm) Arrow-Flex® Radiopaque Polyurethane with Integral Hemostasis Valve/Side Port and Tissue Dilator |
| One: | Spring-Wire Guide, Marked: .035" (0.89 mm) dia. x 17-3/4" (45 cm) (Straight Soft Tip on One End – "J" Tip on Other) with Arrow Advancer™ |
| One: | Catheter: 18 Ga. x 2-1/2" (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle |
| One: | Injection Needle: 22 Ga. x 1-1/2" (3.81 cm) |
| One: | Injection Needle: 25 Ga. x 1" (2.54 cm) |
| One: | Introducer Needle: 18 Ga. x 2-1/2" (6.35 cm) XTW |
| One: | Syringe: 0.75 cc Control Stroke |
| One: | Syringe: 3 mL Luer-Lock |
| Two: | Syringe: 5 mL Luer-Slip |
| One: | 3 ml Applicator Pouch, 2% CHG and 70% IPA ChloraPrep®1 One-Step Solution with Hi-Lite Orange™ Tint |
| One: | 5 ml Ampule HCl, 1% Lidocaine Solution |
| One: | Foil Pack 10% Povidone-Iodine Ointment |
| Two: | Adapter: 2 mm pin |
| One: | Adapter: Tuohy-Borst |
| One: | Dust Cap: Non-Vented |
| One: | Dust Cap: Vented |
| One: | Cath-Gard® Catheter Contamination Shield: 80 cm with Tuohy-Borst Adapter |
| One: | CSR Wrap |
| One: | Drape: 24" x 36" |
| One: | Drape: 24" x 36" with 4" fenestration |
| One: | Alligator Clip |
| One: | Scalpel: #11 |
| One: | Stopcock: 3-way High-Flow |
| Two: | Gauze Pad(s): 2" x 2" |
| Five: | Gauze Pad(s): 4" x 4" |
| One: | Suture: 3-0 Braided Silk with Straight Needle |
Additional information
| Size | 5.0F |
|---|---|
| Arms | N/A |
| Manufacturer | |
| Unit | eaches |
- FDA Product Code: DRF
- FDA Product Code Name: CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING
- GMDN Term Code: 35854
- GMDN Term Name: Temporary cardiac pacing balloon catheter
- GMDN Term Description: A sterile, flexible, balloon-tipped, tube designed to deliver temporary pacing stimuli to the heart; it may detect bioelectric signals from the heart. It is used in the atria and/or ventricles and has electrodes which are usually applied to the ventricles and connect to an external pacemaker that generates the electrical pacing impulses. It may be unipolar or bipolar and facilitate the display of electrocardiographic signals. It is used: 1) in an emergency during bradycardia or asystole until a pacemaker can be implanted to control the heart rate; 2) during and/or after surgery; or 3) during cardiac catheterization [e.g., electrophysiological (EP) examinations]. This is a single-use device.
