Medtronic Sprint Quattro Secure S MRI SureScan Ventricular Defibrillation Lead, Single Coil, Quadripolar, DF-1, IS-1, 58cm
Out of stock
Express: Need it tomorrow? Order in next 2 hours 8 minutes and choose overnight shipping at checkout.
We currently do not have this item in stock, but we can email you as soon as it is available!
The item listed above is expired and may be used for educational, training, and non-clinical research purposes only. Any product information appearing below, including the product indication statement, pertains to an in-date item only.
Description
Medtronic Sprint Quattro Secure S MRI™ SureScan™ Ventricular Defibrillation Lead
The Sprint Quattro™ defibrillator lead is used in tachyarrhythmia management. From lead design to active product monitoring, intentional choices and proactive steps were taken to ensure the reliability of the Sprint Quattro™ defibrillator lead.
Product Code: 694758
- Type: Single Coil, Quadripolar
- Fixation: Active, Extendable/Retractable Helix
- Connector: DF-1, IS-1
- Length: 58cm
Sterilization
- Device Packaged as Sterile: Yes
- Requires Sterilization Prior to Use: No
- Single-Use
- Disposable
Additional Details
- Company Name: Medtronic, Inc.
- FDA Product Code: DTB
- FDA Product Code Name: Permanent Pacemaker Electrode
- FDA Product Code: NVY
- FDA Product Code Name: Permanent Defibrillator Electrodes
- GMDN Term Code: 35853
- GMDN Term Name: Endocardial defibrillation lead
- GMDN Term Definition: An implantable flexible wire with an electrode, insulated with non-conductive material except at its ends, intended to function as an electrical conductor to transmit defibrillation impulses from an implanted cardioverter-defibrillator (ICD) [automatic implantable cardioverter-defibrillator (AICD)] to the endocardium of the right ventricle. It may also be intended to transmit pacing impulses from a cardiac resynchronization therapy (CRT) pulse generator, AICD, or other pacing device. It is typically impregnated with a steroid (e.g., dexamethasone) intended to elute into the tissues to reduce inflammation.
Additional information
| Size | 1 |
|---|---|
| Arms | N/A |
| Manufacturer | |
| Unit | box of 1 |
- FDA Product Code: DTB LWS NVY
- FDA Product Code Name: permanent pacemaker Electrode / Implantable cardioverter defibrillator (non-CRT) / Permanent defibrillator electrodes
- GMDN Term Code: 35853
- GMDN Term Name: Endocardial defibrillation lead
- GMDN Term Description: An implantable flexible wire with an electrode, insulated with non-conductive material except at its ends, intended to function as an electrical conductor to transmit defibrillation impulses from an implanted cardioverter-defibrillator (ICD) [automatic implantable cardioverter-defibrillator (AICD)] to the endocardium of the right ventricle. It may also be intended to transmit pacing impulses from a cardiac resynchronization therapy (CRT) pulse generator, AICD, or other pacing device. It is typically impregnated with a steroid (e.g., dexamethasone) intended to elute into the tissues to reduce inflammation.